G3
![]() |
Category VFFS Load Type Bagmakers |
|---|
Utilities
Electrical
480 VAC +/-5%, 3Ø with ground (PE), 50/60 Hz
7 kVA (7 kW) service required
Electrical system conforms to NFPA 79 and HSWA/IEC 204 (EN60204)
Air Consumption
538 liters/min (19 SCFM) @ 4.8 bar (70 PSI) for 240 BPM
Temperature
Nominal ambient 10-38°C (50-100°F)
Humidity
Less than 90% non-condensing
Film Core Inside Diameter
76 mm (3")
Maximum Film Roll Outside Diameter
432 mm (17")